The Differences Between Powertron Series Tap Boxes

POWERTRON Logo on metal
Category:
Product Note
POWERTRON's Standard Series Tap Box

Standard Series

POWERTRON’s Standard Series Tap Box is the most commonly used and is considered the most basic style. It is typically employed for providing temporary power or load banking a permanent generator. The Standard Series Tap Box is often used in conjunction with other equipment such as breaker panels, transfer switches, and other switchgear.

  • Male Cam-Lock Receptacle
    • cULus 1008
    • Control #: WPVQ
    • Inlet only. Not for use as an outlet
    • Typically used for generator connection
  • Female Cam-Lock Receptacle
    • cULus 1773
    • Control #: XCKT
    • Outlet only. Not for use as an inlet
    • Typically used for load bank connection
POWERTRON's Breaker Series Tap Box

Breaker Series

POWERTRON’s Breaker Series Tap Box offers an upgrade from the Standard Series. This series is commonly used when a breaker or switching device is not directly connected downstream. Facilities such as hospitals, data centers, and major water/wastewater treatment centers may prefer this more redundant system. Additionally, having a breaker inside the tap box can enhance safety during operation and maintenance.

  • Male Cam-Lock Receptacle
    • cULus 1008
    • Control #: WPVQ
    • Inlet only. Not for use as an outlet
    • Typically used for generator connection
  • Female Cam-Lock Receptacle
    • cULus 891
    • Control #: WEVZ
    • Outlet only. Not for use as an inlet
    • Typically used for load bank connection
POWERTRON's MTS Series Tap Box

MTS Series

Given that most tap box applications require power switching, POWERTRON’s MTS Series Tap Box is the ideal choice for controllability between two power sources. Traditionally, tap boxes and manual transfer switches were separate pieces of equipment, leading to increased installation costs, a larger bill of materials (B.O.M.), and more space requirements. The MTS Series Tap Box offers a 2-in-1 solution, making it ideal for smaller commercial facilities ranging from 200A to 1200A.

  • Male Cam-Lock Receptacle
    • cULus 1008
    • Control #: WPVQ
    • Inlet only. Not for use as an outlet
    • Typically used for generator connection
  • Female Cam-Lock Receptacle
    • Manual transfer switches are not intended for use in reverse orientation. Therefore, UL does not provide a UL listing for this category.
Male Cam-Lock
Male Cam-Lock
Female Cam-Lock
Female Cam-Lock